PCR2-ODA Datasheet
PCR2 are bidirectional people counters that use a new type of 24 GHz radar transceiver to detect motion from both directions simultaneously.
The PCR2-ODS is designed for outdoor usage in harsh environments and is IP65 protected. When mounted on a walkway the integrated radar transceiver can count pedestrians walking parallel to the the devices surface.
PCR2-ODS has an integrated 100-240 VAC Power Module allowing to operate the device on mains directly.
Readings are transmitted at regular intervals over a public or private LoRaWAN™ network. All parametric sensors are equipped with a USB configuration port for firmware setup and update.
Features
- Rugged device with protection level against water and dust
- Anonymous people counting by using 24 GHz radar
- Bi-directional
- Interval or totalizer
- LoRaWAN™ data uplink intervals between 1min up to 1 day
- 100-240 VAC Power Supply
- Configuration via USB-Port or LoRaWAN™ Downlinks
- Pole or surface mount
- Firmware updates over USB
- Free Lifetime firmware updates
- Swiss made
- 24 months warranty
Applications
- Outdoor People Counting in remote areas
- Slow objects counting
- Security
Technical Specification
Note: This technical specs relate to Firmware 4.0
Side Mounting
When mounted at a wall or at a pole, PCR2-ODS can detect people passing by in both directions on walkways 0.5m up to 5m wide.
IMPORTANT: Persons walking side-by-side will be counted as one person.
Tilted
The device can be mounted at a pole at around 3m facing towards the walkway. Our pole mount MT80-10 (accessory) can be used for that.
IMPORTANT: Persons passing by walking side by side ca not be separated and will be counted as one person.
Mechanical Specs
| Mechanical | |
|---|---|
| Size (L x W x H) | 150 x 150 x 60mm |
| Weight | 830g |
| Protection class (IEC 60529) | IP65 |
| Wall mount holes behind hinged caps |
Radar
| Radar Detection | |
|---|---|
| Frequency | 24GHz |
| Beam Aperture | 80° / 34° |
| Range | 50-500cm |
| Movement detection | bi-directional |
| Movement speed | 1-20 km/h |
| Mounting | side mounting tilted |
| Counting modes | interval totalizer |
LoRaWAN® Modem
| LoRaWAN® | |
|---|---|
| LoRaWAN® Specification | LoRaWAN® 1.0.3 Regional Parameters v1.0.3revA |
| Device Classes | A or C |
| LoRaWAN® Features | OTAA, ADR, LinkCheck, DeviceTime |
| LoRaWAN® Payloads | DeviceID (9 bytes), AppData (10 bytes) |
| Antenna | internal monopole, dual-band 868-870 MHz, 902-928 MHz |
| Antenna Gain | 0.3 @ 868 MHz, 1.0 @ 902 MHz |
| Region | Channel Datarate | Channels | Channel Groups | Max EIRP |
|---|---|---|---|---|
| EU868 | DR0-DR7 | 3 (863-870 MHz) | n/a | 16.0 dB |
| AS923 | DR0-DR7 | 2 (915-928 MHz) | AS923-1 only | 16.0 dB |
| US915 | DR0-DR4 | 64+8 (902-928 MHz) | All FSB1 FSB2 FSB3 FSB4 FSB5 FSB6 FSB7 FSB8 |
20.0 dB |
| AU915 | DR0-DR6 | 64+8 (915-928 MHz) | FSB1 FSB2 FSB3 FSB4 FSB5 FSB6 FSB7 FSB8 |
20.0 dB |
Power Options
AC
| AC Power Input | |
|---|---|
| Input voltage | 100 – 240 VAC |
| Input frequency | 50 / 60 Hz |
| Input current at full load | 80 mA / 55 mA typ. |
| Recommended external input fuse | 1.0 A slow blow |
Scope of delivery
- 1x PCR2-ODA
- 1x QuickStart Manual
Ordering Information
The order number (SKU) is composed as follows
| Region (*) | ||
|---|---|---|
| PCR2 | -EU868 | -ODA |
Accessories
| SKU | Description | Used for |
|---|---|---|
| MT80-15 | Mounting Bracket, stainless steel, 80° tiltable | mounting PCR2-ODS on a pole tilting down to the walkway |
| WPMB | Pole Mounting Bracket, ASA plastics, fixed angle | mounting PCR2-ODS to a vertical or horizontal pipe w/o beside the walkway |