PCR2-OD Datasheet

PCR2-OD

PCR2 are bidirectional people counters that use a new type of 24 GHz radar transceiver to detect motion from both directions simultaneously.

The PCR2-OD is designed for outdoor usage in harsh environments and is IP65 protected. When mounted on a walkway the integrated radar transceiver can count pedestrians walking parallel to the the devices surface.

Readings are transmitted at regular intervals over a public or private LoRaWAN™ network. All parametric sensors are equipped with a USB configuration port for firmware setup and update.

Features

  • Rugged device with protection level against water and dust
  • Anonymous people counting by using 24 GHz radar
  • Bi-directional
  • Interval or totalizer
  • LoRaWAN™ data uplink intervals between 1min up to 1 day
  • Configuration via USB-Port or LoRaWAN™ Downlinks
  • Pole or surface mount
  • External power supply 5-12V DC or USB
  • Firmware updates over USB
  • Free Lifetime firmware updates
  • Swiss made
  • 24 months warranty

Applications

  • Outdoor People Counting

Technical Specification

Note: This technical specs relate to Firmware 4.0

Side Mounting

When mounted at a wall or at a pole, PCR2-OD can detect people passing by in both directions on walkways 0.5m up to 5m wide.

IMPORTANT: Persons walking side-by-side will be counted as one person.

Wall mounting

Tilted

The device can be mounted at a pole at around 3m facing towards the walkway. Our pole mount MT80-10 (accessory) can be used for that.

IMPORTANT: Persons passing by walking side by side ca not be separated and will be counted as one person.

Mechanical Specs

Mechanical
Size (L x W x H) 100 x 100 x 40mm
Weight 427g
Protection class (IEC 60529) IP65
Wall mount holes behind hinged caps

Radar

Radar Detection
Frequency 24GHz
Beam Aperture 80° / 34°
Range 50-500cm
Movement detection bi-directional
Movement speed 1-20 km/h
Mounting side mounting
tilted
Counting modes interval
totalizer

LoRaWAN® Modem

LoRaWAN®
LoRaWAN® Specification LoRaWAN® 1.0.3
Regional Parameters v1.0.3revA
Device Classes A or C
LoRaWAN® Features OTAA, ADR, LinkCheck, DeviceTime
LoRaWAN® Regions EU863-870
AS923
AU915-928 (8 selectable sub-bands)
US902-928 (8 selectable sub-bands)
IN865-867
Antenna internal monopole, dual-band
868-870 MHz, 902-928 MHz
Antenna Gain 0.3 @ 868 MHz, 1.0 @ 902 MHz
Region Channel Datarate Channels Channel Groups Max EIRP
EU868 DR0-DR7 3 (863-870 MHz) n/a 16.0 dB
AS923 DR0-DR7 2 (915-928 MHz) AS923-1 only 16.0 dB
US915 DR0-DR4 64+8 (902-928 MHz) All
FSB1
FSB2
FSB3
FSB4
FSB5
FSB6
FSB7
FSB8



20.0 dB
AU915 DR0-DR6 64+8 (915-928 MHz) FSB1
FSB2
FSB3
FSB4
FSB5
FSB6
FSB7
FSB8
20.0 dB

Power Options

DC

DC Power
Terminals 2 Cage Clamp, Push-In
Recommended Wire Diameter 12-22 AWG (0.2 – 0.75mm²)
Voltage 5V-12VDC
Current 25mA @ 5VDC
19mA @ 12VDC

Scope of delivery

  • 1x PCR2-OD
  • 1x QuickStart Manual

Ordering Information

The order number (SKU) is composed as follows

Region (*)
PCR2 -EU868
-AS923
-US915
-AU915
-OD

(*) LoRaWAN® Region can be changed by using the command line interface.


Accessories

SKU Description Used for
MT80-10 Bracket for PCR2-IN, PCR2-OD, 80° tiltable tilted mounting above doors
PSU12 12V Power supply, IP67 rated, industrial grage fix installations power supply